Touch Probe (TP) edge evaluation only possible with positive edge (remedied from V1.2)
Remedied from:
ECS Motion V1.2
Behaviour of new version?
The detection of the zero pulse or touch probe is not enabled until the drive has left the limit switch. As a result, it is ensured that the home position is always reached.
Which products are affected?
ECSxM V1.1
What happens?
The edge evaluation of the touch probe only works in combination with a positive edge.
When does the problem occur?
In case of touch probe evaluations with negative edge direction.
Possible diagnostics?
Diagnostics via the ECSxM control.
Short-term measures/recommendations?
None.
Evaluation:
Since this behaviour already occurs during commissioning the edge direction can be influenced from the hardware side thus ensuring that the function can be implemented.
Published with service message No. 2007/38 und 2007/39