Which products are affected?
ECS axis module ECSxx series, operating software V7.0
Function description
TheAIF_IO_Management system block has been extended by the following system variable:
Inputs (Inputs_AIF_Management) AIF_bFieldBusStateBit8_b … AIF_bFieldBusStateBit15_b
Output (Outputs_AIF_Management) AIF_wControl
Applications
The system variables are used to implement the communication between the AIF module and PLC target system. The assignment / function of the system variable depends on the AIF module used.
Taxonomy:
ECSxA application
,
ECSxE power supply module
,
ECSxK capacitor module
,
ECSxM motion
,
ECSxP position and shaft
,
ECSxS speed and torque
,
ECS servo inverters
AKB-ID:
200603150
Last update:
2023/09/08
Category:
Informations sur la version
Lenze reserves the right to change information on this page at any time. Any liability for the accuracy of the information is excluded.