If user management is enabled, it is no longer possible to go online with Easy Starter after updating from V1.8 to V1.9

Question:
Why does an EASY Starter online connection to a C5xx controller with active user management require login credentials after updating from firmware V1.8.1.3021 to V1.9.0.3470?

Answer:
After updating a C5xx controller with active user management from firmware V1.8.1.3021 to V1.9.0.3470, EASY Starter may no longer establish an online connection without entering a username and password.

The behavior is as follows:

  • With firmware V1.8.1.3021, EASY Starter can establish the online connection without requesting credentials.
  • After updating to V1.9.0.3470, access may still work without credentials during the first startup of the controller.
  • From the second startup onward, EASY Starter requires authentication.
  • The same behavior can occur after a controller replacement.

Workaround:

  1. When establishing the EASY Starter connection, enter the administrator username and password from the user management configuration created for the controller.
  2. Alternatively, recreate the user management configuration on the controller.

The administrator account to be used is the account from the customer-specific user management configuration, not an arbitrary or separate administrator account.