L_TT1P_TechnologyModules_LM (from V03.26.01)
L_MC2P_MotionControlCam (from V03.26.01)
(Update via Easy Package Manager)
Response of the new version:
The position of the axis remains constant when disengaging.
What happens?
The position of the axis jumps by a whole curve cycle.
When does the behaviour occur?
- The position of the coupling coefficient is noisy and unfiltered.
- The function "disengage" leads to a jump in the position of the axis.
Which products are affected?
Technology module L_TT1P_FlexCamState from library L_TT1P_TechnologyModules_LM
Short-term measures:
One of these two measures can be applied.
a. Position of the conductance can be smoothed via filter function
b. Use of the technology module L_TS2P_FlexCamSate from the library L_TS2P_TechModulesSynchronizingCamming
Evaluation / recommendations:
It is generally recommended to smooth a noisy position signal by filtering. Furthermore, the tracking error monitoring should always be active in order to detect discontinuities in the profiles.
Automatic Translation