Corrected from:
Library: L_TT1P_TechnologyModules_LM (from V03.23.00.14)
Update via Easy Package Manager
Behaviour of new version:
Error corrected, starting is possible after xPathHold = TRUE.
Description of the behaviour::
The technology module can no longer be started after xPathHold = TRUE.
Under what conditions does the behaviour occur?
One of the two situations listed below is triggered on the technology module.
xBusy:=TRUE
xInPosition:=TRUE
xPathHold:=TRUE
OR
xPathHold:=TRUE
xBusy:=FALSE
xInPosition:=FALSE
eTMState:=READY
Setting xExecutePickAndPlace again no longer starts motion control.
Affected products:
Technologiemodul L_TT1P_PickAndPlace from library L_TT1P_TechnologyModules_LM (from V03.18.01.04)
Short-term measures:
After setting xAbort = TRUE a motion control is restarted.
Automatic Translation