Behaviour of new version:
The correction process for the technology module Register Control is always terminated without jump.
What happens?
The correction process for position correction of the RegisterControl technology module is completed with a jump.
When does this behaviour occur?
The behaviour occurs always. Since the not corrected position differences are adding up, the error mainly shows effect when using a mark stack.
Which products are affected?
L_TT1P_RegisterControlState function block from the L_TT1P_TechnologyModules_LM library (V3.12.0.9 and higher)
Short-term measures:
If possible, do not use the mark stack in this technology module version.
As an alternative, you can use an earlier technology module version.