Corrected from:
EASY UI Designer V1.9
Behavior of the new version:
Variables of type UNION are detected when browsing variables and are not included in the Visu's variable scope. This prevents the use of this data type, thereby avoiding errors.
Description of behavior:
If an object of type UNION is used in the PLC project, importing and using it in the EUID results in errors. This applies both to its use as a single variable and as an element in a structure.
Conditions under which the behavior occurs:
- Symbol configuration contains an element of type UNION
- Connection of the UNION element in the EUID
Affected products:
EASY UI Designer V1.8
Short-term measure, recommendations, evaluation:
Please do not include UNION elements in the symbol configuration for use in the visualization.
[Automatic Translation]