Error messages when compiling a project for 'i950 Extended for customer-specific devices only'

Corrected from:

-

Behavior of the new version: 
-

 

Description of behavior:
When compiling a project in PLC Designer, the following compiler errors occur:

[ERROR]         visuelembase, 4.8.0.0 (system): Visu_FbClearEventsAfterStart: C0086:  No definition found for interface 'CmpEventMgr_Interfaces.ICmpEventCallback'

[ERROR]         visuelembase, 4.8.0.0 (system): Visu_FbClearEventsAfterStart: C0077:  Unknown type: 'CmpEventMgr_Interfaces.ICmpEventCallback'

[ERROR]         visuelembase, 4.8.0.0 (system): Init [Visu_FbClearEventsAfterStart]: C0032:  Cannot convert type 'VISU_FBCLEAREVENTSAFTERSTART(visuelembase, 4.8.0.0 (system))' to type 'CmpEventMgr_Interfaces.ICmpEventCallback'

[ERROR]         visuelembase, 4.8.0.0 (system): Init [Visu_FbClearEventsAfterStart]: C0032:  Cannot convert type 'CmpEventMgr_Interfaces.ICmpEventCallback' to type 'ICmpEventCallback(cmpeventmgr, 3.5.12.0 (system))'

     

Conditions under which the behavior occurs: 
The above compiler error messages occur when a project with an 'i950 Extended for customer specific devices only' is created in combination with a CODESYS WebVisu with a PLC Designer lower than V4.1 and then opened in PLC Designer V4.1.

Affected products: 
PLC Designer V4.1

Short-term measures, recommendations, evaluation: 
Continue to edit affected projects with a PLC Designer version ≤ V4.0.1.

[Automatic Translation]

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202500428/1/