EASY Starter: Upload *.lda file: It may be necessary to stop the application to shorten the loading time and avoid timeout errors.

     

     

Fixed as of:

Servo inverter i950 FW V01.xx.xx: (no change planned)
Servo inverter i950 FW with new hardware: from V02.00.xx (planned)
Behavior of the new version:
No improvement is possible for the existing device hardware and firmware V01, and accordingly no change to the FW is planned.
(planned):
Only with the new i950 device hardware and the associated i950 FW from V02.00.xx onwards will it be possible to upload in a significantly shorter time. 
 
Description of behavior:
EASY Starter: Uploading application data from multiple i950 devices for storage as an *.lda file on the PC can take up to several minutes under certain circumstances, which is significantly longer than expected.
In extreme cases, when the application is running, the timeout monitoring may be triggered and an error message may appear.

Conditions under which the behavior occurs:

  • The inverters are enabled, the application is running, and 
  • theapplication data isuploaded via EASY Startertobe savedasan*.lda file.
  • E.g.: i950 with TA Sync And Correction as system bus master (EtherCAT onboard).

Affected products:
Servo inverter i950 FW

Short-term measures,recommendations,evaluation:
The loading time can be reduced by stopping the PLC application using device command 0x2022:45. In particular, this prevents the timeout monitoring from being triggered.
When the PLC application is stopped, significantly more computing time isavailable for uploading, and the duration of the process is reducedaccordingly.