Error message "The logical device 'xxx' is mapped to more than one device" during compilation (fixed as of V4.1.0)

​Fixed as of:
PLC Designer V4.1

Behavior in the new version:
After renaming the Safety I/O modules, the project can be compiled without errors.
 
Description of the behavior:
When compiling the PLC project, the following error message appears:
The logical device “xxx” is mapped to more than one device. 

Under what conditions does this behavior occur?
The error message described above occurs when the Safety I/O modules were imported into the PLC project via bus scan and were subsequently renamed.

Affected products:
PLC Designer

Short-term measures:
Manually insert the Safety I/O modules into the PLC project.

Assessment/Recommendations:
This functional limitation may occur during the project configuration phase and will be detected at the latest when the project is downloaded.
[Automatic Translation]
URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202200253/1/