Corrected from:
L_TS2P_TechModulesSynchronizingCamming (from V3.24.0)
(Update via Easy Package Manager)
Response of the new version:
The state of the TM changes to eTMState= CAMMING as soon as a safety or limiter function becomes active.
What happens?
The state of the TM L_TS2P_FlexCam remains unchanged at eTMState= CAMMING, although a safety or limiter function (SS1, SS2, etc.) is active.
When does the behaviour occur?
The TM L_TS2P_FlexCam moves a cam plate and the limiter function SDiPos is activated. The axis is brought to a standstill when the speed is positive.
Which products are affected?
TM FlexCAM (L_TS2P_FlexCAMState from library L_TS2P_TechModulesSynchronizingCamming).
Short-term measures:
none
Evaluation / recommendations:
The limiter function is given. In the event of an error, a false status is reported, but this does not affect the function.