GSDML device description files for Lenze Profinet IO communication modules

Description:
By means of the GSDML-files, which you can download here, you are able to contain the Lenze communication modules in the Profinet IO configuration software (Siemens STEP 7 etc).

System requirements:
The single GSDML-files describe the implemented Profinet IO functionalities of the corresponding communication modules. For the following communication modules GSDML-files are available:   
  • 1_Servo Inverter (i950, 9400)
  • 2_Inverter Drive (i550, 8400, 8400 Motec and 8400 Protec)
  • 3_IO Systems
  • 10_Controller_Panel
Software installation:
Unpack the ZIP-file in any directory of your computer and insert the GSDML-files in the configuration software.

9400 Note:
The GSDML file 'GSDML-V2.0-Lenze-9400PN-20070102.xml' can be used for firmware version 0.50 of the E94AYCER Profinet I/O communication module.

Due to the integration of the 'PROFIsafe' safety protocol the new GSDML device description file, GSDML-V2.0-Lenze-9400PN100-20070901.xml, has been created for firmware versions 0.70 and 1.01. It is not possible to exchange modules equipped with different firmware versions. Every firmware version can only be operated in combination with the corresponding GSDML file! As a result, the Profinet master must be reconfigured when a module with firmware version 0.50 is exchanged for a module equipped with 0.70 or 1.01.
Due to the integration of the internal Ethernet Switch functionality and the Networktopologyidentification the new GSDML device description file, GSDML-V2.1-Lenze-9400PN110-20081118.xml, has been created for firmware versions 1.10.

The GSDM file GSDML-V2.2-Lenze-9400PN130-20110331.xml can be used with firmware version 1.10 and 1.30 and has only new error text included. Moduls with firmware version 1.30 can also work with the GSDML file  GSDML-V2.1-Lenze-9400PN110-20081118.xml.

8400 Protec Note:
The GSDML file GSDML-V2.2-Lenze-8420PN120-20100330.xml can be used with Protec-Profinet firmware version 01.04 and the GSDML file GSDML-V2.2-Lenze-8420PN120-20101207.xml can be used with Protec-Profinet firmware version 02.00 onwards.

8400 StateLineC, HighLineC and TopLineC Note:
The GSDML file 'GSDML-V2.2-Lenze-8400PN100-20100423.xml' can be used with MCI-Profinet firmware version 01.00 and the GSDML file 'GSDML-V2.2-Lenze-8400PN100-20110406.xml' can be used with MCI-Profinet firmware version 02.01 onwards.

8400 Motec Note:
The GSDML file 'GSDML-V2.2-Lenze-8440PN200-20110713.xml' can be used with 8400 Motec Profinet firmware version 02.02 onwards.
 

Further helpful information: